PR-4N350

AURA-SMPR

synchrophasor monitoring system

  • IEEE C37.118
  • IEC 60870-5-104
  • IEC 61850-8-1 GOOSE
  • IEC 61850-9-2
  • high measurement accuracy

PR-4N and PR-4T measuring transducers measure instantaneous and phasor values of AC voltage and current, monitor volt-free contact states, and transmit this information over Ethernet to higher-level measurement systems.

Request a quote

These versatile measuring transducers use modern components to support automation systems on a common hardware platform from one manufacturer, including synchrophasor monitoring, SCADA, disturbance recording and fault location. IEC 61850 support and standard communication protocols allow integration into existing process control systems. PR-4N and PR-4T transducers measure instantaneous and phasor values of AC voltage and current, monitor volt-free contact states, and transmit the information over Ethernet to higher-level measurement systems.

Design

The transducers are housed in plug-in plastic enclosures. The cover is secured to the connector section with four screws and has two latches that lock the transducer into its mating connector. The input connector is similar to a conventional BI-6 test block. It shorts the current circuits when the transducer is withdrawn and permits current-injection testing and insulation testing of incoming cables. Guide ribs between connector contacts prevent short circuits if the transducer is accidentally tilted during insertion. The mating connector has M4 screw terminals for the input and output circuits.

Applications

The transducers are used in digital fault recorders, synchrophasor measurement and monitoring systems, SCADA systems and other automated information and measurement systems at power utilities and industrial facilities.

Several versions are available with different input signal types and measurement ranges. Every version has four independent measurement channels and four binary inputs for volt-free contacts.

Available transducer variants
Designation Analog inputs Binary inputs
Current Voltage
PR-4N350 - 4 (350 V AC) 4 (24 V DC)
PR-4T20 4 (20 A AC) - 4 (24 V DC)
PR-4T200 4 (200 A AC) - 4 (24 V DC)

For analog inputs, the value in parentheses is the measurement range in RMS AC current or voltage. For binary inputs, it is the nominal operating voltage.

PR-4N350
AC voltage transducer
PR-4T200
AC current transducer
The following communication protocols are supported.
  • IEEE C37.118 for synchrophasor measurement systems
  • IEC 60870-5-104 for SCADA systems
  • IEC 61850-8-1 GOOSE for transmitting binary input states
  • IEC 61850-9-2 for transmitting instantaneous analog values
  • HTTP for the commissioning web interface
Measurement accuracy (intrinsic relative error)
  • voltage and current: ±0.2%
  • synchrophasor angle ±0.2°
  • frequency: ±0.001 Hz
Transducer overall and mounting dimensions
Transducer module overall and mounting dimensions
Voltage transducer connection diagram
Current transducer wiring diagram
Functions Communication protocols Software Note
Synchrophasor monitoring system IEEE C37.118 (TCP, UDP) AuraPDC Connect to an accuracy class 0.5 current-transformer core. AURA-SMPR and AURA SCADA functions can operate simultaneously.
SCADA IEC 60870-5-104 AuraMaster
Digital Fault Recorder (DFR) COMTRADE, IEC 60870-5-104 AuraServ, Aura2000, PostAWR, TeleAURA Connected to a class 10P CT core. AURA recording, AURA-61850 and fault location functions are implemented in a single hardware and software system.
IEC 61850 (GOOSE, SV) AuraRec
Fault location FTP, SMB Aura2000